(1) RS232/RS485: Choose RS232 or RS485 for activated.
(2) RS232/RS485 ID: This entry is used to assign each device with its own ID code, when more than on unit is
used in one system through RS232/RS485.
There are two ID code for the Digital video recorder : 001 or 002
(3) BAUD RATE: There are 6 different speeds that can be used to transmit instruction or
information through the RS232/RS485 port on the device, 1200 baud,2400 baud,4800 baud,9600 baud,
19200 baud,and 3840 baud. The default setting from the factory is 9600 baud.
(4) PARITY: Select parity lever: NONE/ODE/EVEN
(5) DATA BIT: Select data bit : 8 or 7
(6) STOP BIT:Select stop bit: 1 or 2