2.3.1. Address Setting
The address code of the EPTZ1000 should be set to correspond properly with a
control device to control multiple dome cameras. The address codes are made up by the
dipswitch SW1 (8 bits) on the PCB board. The 8 bits dipswitch indicates the binary coded
of the address, and there are 256 addresses can be selected (0 ~ 255, 2
8
= 256). It also
means that there up to 256 dome cameras can cascade on the RS485 bus. The
dipswitch setting and the indicated address are represented in the following chart.
Note: The factory default address is 1.
Notice: Please make sure the power is off before setting, and restart the EPTZ1000 to
enable a new value after changing.