- 71 -
PC Operation mode
Select the "Other" tab
In this menu, the PC operation mode is defined:
Receiver and Client: default setting, standard setting for single user installation
Receiver only: "server" mode, the PC only receives and distributes network
alarms to other client PCs
Client only: PC only receives network alarms distributed by servers
working in "Receiver only" mode
RECEIVER AND CLIENT
Standard mode for single user installations. Activate the checkbox "Notify Powercon" if
alarm messages shall additionally be displayed in the PowerCon notification window. The
IP address 127.0.0.1 is the local host IP address and should not be changed.
RECEIVER ONLY
"Server" mode, the PC only receives and distributes network alarms to other client PCs.
The IP addresses of the client PCs receiving the network alarms are entered in the list
"Alarm Clients".
CLIENT ONLY
PC only receives network alarms distributed by servers working in "Receiver only" mode.
No additional IP address settings are required.
PROTOCOL
The protocol type must comply with the protocol type of the alarm transmitter DVR.
Alarm transmission from server to client always works in UDP mode.
If the system contains DVRs with different protocol types and ports, activate the
checkbox “TCP and UDP”.
UDP PORT
UDP ports for alarm transmission from server to client PCs.
ATTENTION: These ports are not related to the DVR port settings
ALARM SOUND:
Select a *.wav format sound file for alarm notification
Comentários a estes Manuais