¾ RS232 Data Bit: This field is the data bit at which you will be transferring. There
are two settings for this option: 8 or 7. The default is set to 8. To change this,
simply use the Jog Dial on the DVR to make your selection.
RS485:
¾ RS485 Baud Rate: This field is to set the speed at which is
used to transmit instruction or information through the
RS485 port on the DVR. There are six different speeds,
2400, 4800, 9600, 19200, 38400 and 57600BPS. The default
setting from the factory is 9600 BPS. To change this, simply
use the Jog Dial on the DVR to make your selection.
¾ RS485 Stop Bit: This field is to set the stop bit for the RS485 connection. There
are two different stop bits, 1 or 2. The default in the DVR is set to 1. To change
this, simply use the Jog Dial on the DVR to make your selection.
¾ RS485 Parity: This field is to select the parity level at which you will be
connected. You can choose between None, Odd, or Even parity levels. Default is
set to none. To change this, simply use the Jog Dial on the DVR to make your
selection.
¾ RS485 Data Bit: This field is the data bit at which you will be transferring. There
are two settings for this option: 8 or 7. The default is set to 8. To change this,
simply use the Jog Dial on the DVR to make your selection.
¾ RS232/RS485 ID: This entry is used to assign each device its own ID code if
more than one unit is used through the RS232/RS485 connection. There are two
ID codes for the DVR: 001-255. The default is set to 001. To change this, simply
use the Jog Dial on the DVR to make your selection.
¾ PTZ PROTOCOL: Select PTZ protocol from EVERFOCUS, PELCO-D,
PELCO-P and ED2200/2250.