EverFocus Navigation Access Control Management Software
48
4) Click “Modify” button to change the related information of the reader.
4.1.5.3 Alarm input setting
FLEX II series controller has alarm input setup options. On the alarm input setup page, the user
can configure the alarm input of the main modules and alarm modules of the controller,
respectively set the name of each input, fire alarm or not, input mode, output mode, delay time,
alarm duration, door action when a fire alarm appears and alarm output of various alarm relays
when an alarm appears. The corresponding alarm output settings include door alarm and alarm
output. When a door alarm takes place, door relay works. During alarm output, the main, slave
relays and defence relay work.
Name: 10 alarm input names that can be any names desired.
Fire alarm: designate whether an alarm input of certain number is fire alarm input.
Input mode: alarm input mode, disabled: the defence alarm input is invalid. Normally open: this
input opened in normal state, alarm input enabled after closing. Normally closed: this input
closed in normal state, alarm input enabled after being opened.
Output mode: the mode that the alarm output responds to the input after an alarm is input.
Straight-through: with an alarm input, the alarm output is activated at once; after alarm input
stops, the alarm output stops immediately. At this time, alarm duration does not work. Latching:
with an alarm input, the alarm output is activated at once; no matter the alarm input stops or not,
alarm output continues until the alarm duration is over.
Delay time: the duration between the time when the alarm input of certain number is armed and
the time when the alarm input works.
Alarm time: indicates the time of various alarm relays output when the alarm of certain number
is with an input.
Door alarm: indicates whether various door relays respond to the alarm input when the alarm of
certain number is with an input.
Alarm output: indicates whether various defence area relays respond to the alarm input when
the alarm of certain number is with an input.
Door behaviour under file alarm: indicates the opening actions of various doors when there is
a fire alarm input.
Operating procedure:
1) Click alarm input tab.
2) Select the alarm input of certain number to be set from the alarm input list.
3) Select the name, fire alarm or not, input mode, output mode, delay time, alarm time, door
action when a fire alarm appears and alarm output of various alarm relays when an alarm
appears in the alarm input information box.
4) Click the “Modify” button to change the related information of the alarm input.
4.1.5.4 Alarm setting
The FLEX I series controller and FLEX II series controller have different contents in alarm setting,
wherein FLEX II series controller performs alarm input and output of the main modules and
alarm modules in “alarm input” separately. Take the FLEX I series controller as an example. On
the alarm setup page, the user may configure the alarm output of the designated controller.
Alarm output settings include: main module output, slave module output, door module output,
alarm module output and so on of various alarms.