EverFocus Navigation Access Control Management Software
50
the “expired card” line.
Invalid card: to disable a card, set it to be an invalid card. An invalid card is not permitted for
access to the ACCESS SYSTEM, but if it is used on the card reader, an “invalid card” event will
appear, and the controller will give out alarm output according to the settings of the “invalid card”
box.
Invalid door area: each card is subject to a control level. For each level, the system
administrator can assign the control prerogative for certain door areas for certain time sections. If
the card is not used in the door area with an access right, an “invalid door area” event will be
generated, and the controller will give out alarm output according to the settings of the “invalid
door area” box.
Invalid time section: each card is subject to a control level. For each level, the system
administrator can assign the control prerogative for some door areas in some time sections. If
the door area has no release right in a certain time section and a card is used in this door area,
an “invalid time section” event will be generated. The controller will give out alarm output
according to the settings of the “invalid time section” box.
Anti-Pass-Back (APB): a control function to prevent the cardholder from repeatedly using the
card for entry into the same area without leaving. To perform anti-Pass-Back, two card readers
for entrance/exit can be designed. The cardholder must swipe the card on the entrance and exit
card readers alternately.
When the card is set to have anti-pass-back function, if the cardholder attempts to enter by using
the card on the card reader for twice successively, the access right will be refused and the
system will generate an illegal event.
When the door of the ACCESS SYSTEM has the card reader on one side only, if anti-pass-back
function is set, the cardholder will be incapable of passing the door.
If the card is set to have anti-pass-back attribute, when the card is used over twice successively
on the entrance card reader or exit card reader (can be different card readers), a card
anti-pass-back event will be generated, and the controller will give out alarm output according to
the settings of the “anti-pass-back” box.
Card password error: when a card with password is used on a card reader but fails to pass for
the password input error of three times successively, a “card password error” event will be
generated, and the controller will give out alarm output according to the settings of the “card
password error” box.
Door opening timeout: when the time of a door in open state exceeds the allowed time set by
the system administrator, an “opening timeout” event will be generated, and the controller will
give out alarm output according to the settings of the “door opening timeout”.
Missing of card reader: when the controller detects that the card reader is not connected with
the system, a “missing of card reader” event will appear, and the controller will give out alarm
output according to the settings of the “missing of card reader” box.
Duress opening: in case of an illegal card use and failure to perform a leaving request, but the
magnetic sensor of a door shows to the controller that the door has been opened, a “duress
opening” event will be generated, and the controller will give out alarm output according to the
settings of the “duress opening” box.
Main: main output on the Mainboard.
Slave: slave output on the Mainboard.
Door 1 ~ Door n: output of Door n modules.
Alarm 1~Alarm 8: alarm output 1 to alarm output 8.
N: this type of alarm input has no alarm output.
L: alarm output can be triggered by the same type of alarm for the same module.
A: this kind of alarm of any module can trigger an alarm output.
Operating procedure:
1) Click alarm tab.
2) Select or click alarm output settings in the alarm output information box.
3) Click the “Modify” button to change the related information of the alarm output.
4.1.5.5 Alarm time setup
On the alarm time setup page, the user may configure the alarm time of the designated controller.
The alarm time setup is used to set the time period of the alarm.